3 Basic Requirements
3.1 Types of Storage Tanks
3.1.1 A low temperature steel storage tank may be a single containment tank,a double containment tank or a full containment tank.
3.1.2 A single containment tank may be a single containment tank without outer shell(Figure 3.1.2-1)or a single containment tank with outer shell(Figure 3.1.2-2).
![img](https://epubservercos.yuewen.com/7D8EBE/19825690408903306/epubprivate/OEBPS/Images/txt003_1.jpg?sign=1739006027-VZ1rBRBVJo5xrKHjUbmEoLk2tHsX5417-0-e863d4319eb3d4049738ad93857534e2)
Figure 3.1.2-1 Single containment tank without outer shell
1-Foundation heating system;2-Foundation;3-Bottom insulation;4-Primary container(steel);5-Flexible insulating seal;6-Suspended roo(finsulated);7-Roo(fsteel);8-External shell insulation;9-External water vapour barrier;10-Bund wall
![img](https://epubservercos.yuewen.com/7D8EBE/19825690408903306/epubprivate/OEBPS/Images/txt003_2.jpg?sign=1739006027-WALqHXQJt7KQBBwPUDUWoQLoaabv5Iq6-0-e3a7083d3b80ca840886e146c5edf6dc)
Figure 3.1.2-2 Single containment tank with outer shell
1-Foundation heating system;2-Foundation;3-Bottom insulation;4-Primary container(steel);5-Flexible insulating seal;6-Suspended roof(insulated);7-Roof(steel);8-Lose fill insulation;9-Outer shell(steel);10-Bund wall
3.1.3 A double containment tank may consist of a primary container and a secondary steel container(Figure 3.1.3-1)or a primary container and a secondary concrete container(Figure 3.1.3-2).The annular space,between the primary and secondary containers,should not be more than 6.0m.
3.1.4 A full containment tank may consist of a primary container and a secondary steel container(Figure 3.1.4-1)or a primary container and a secondary concrete container(Figure 3.1.4-2).The annular space,between the primary and secondary containers,should not be more than 2.0m.
![img](https://epubservercos.yuewen.com/7D8EBE/19825690408903306/epubprivate/OEBPS/Images/txt003_3.jpg?sign=1739006027-6yyNqamBFyL6HaQjKF7JEyvjJ3uTxT58-0-6e87ffe1e8775a14301e6a013971e610)
Figure 3.1.3-1 Double containment tank with secondary steel container
1-Foundation heating system;2-Foundation;3-Bottom insulation;4-Secondary container(steel);5-Primary container(steel);6-Flexible insulating seal;7-Suspended roo(finsulated);8-Roo(fsteel);9-Cover(rain shield);10-External insulation;11-External water vapour barrier
![img](https://epubservercos.yuewen.com/7D8EBE/19825690408903306/epubprivate/OEBPS/Images/txt003_4.jpg?sign=1739006027-hIHwDpbuGXM8PLiOJv9rM12EuwxJ1Ye4-0-834f45172ca2b61a1fd41e8ea66de5ea)
Figure 3.1.3-2 Double containment tank with secondary pre-stressed concrete container
1-Foundation heating system;2-Foundation;3-Bottom insulation;4-Secondary container(concrete);5-Primary container(steel);6-Flexible insulating seal;7-Suspended roof(insulated);8-Roof(steel);9-Cover(rain shield);10-Lose fill insulation;11-Outer shell(steel)
![img](https://epubservercos.yuewen.com/7D8EBE/19825690408903306/epubprivate/OEBPS/Images/txt003_5.jpg?sign=1739006027-vAyEDahBHS4LONt2Tpg2Rg3nXJMRdttH-0-eebf3ae121bf00b6b56fdad6217cf111)
Figure 3.1.4-1 Full containment tank with secondary steel container
1-Foundation heating system;2-Foundation;3-Bottom insulation;4-Secondary container(steel);5-Primary container(steel);6-Flexible insulating seal;7-Suspended roof(insulated);8-Roof(steel);9-Loose fill insulation
![img](https://epubservercos.yuewen.com/7D8EBE/19825690408903306/epubprivate/OEBPS/Images/txt003_6.jpg?sign=1739006027-Gl2NG94Id1SXftfsgBL8LQujmnaYof8u-0-81ea6a78113b53fdfa990e8b3f152dcc)
Figure 3.1.4-2 Full containment tank with secondary pre-stressed concrete container
1-Foundation heating system;2-Foundation;3-Bottom insulation;4-Primary container(steel);5-Flexible insulating seal;6-Suspended roof(insulated);7-Roof(concrete);8-Insulation on inside of pre-stressed concrete outer tank;9-Secondary container(concrete)